Effective R-Value: 32.7
Typical Concrete PSI: 7,000 PSI
Weight PSF: 75 Lbs
Wind Load: 140 MPH minimum
Wind Load with HollowCore: 190+ MPH
Sound Transmission (STC): 60+
Fire Rating: 3.5 Hours
Seismic Rating: Seismic Design Zones A, B, C & D
Connector Shear Strength: 910 Lbs per connector
Water Vapor Permeance: .54 perms (vs. 2.5 for CMU)
Maximum Panel Dimension: 32’ by 12.5’ (limited by trucking)
Maximum 8” Hollowcore Span: 32 FT
Reinforcing: Light Gauge Wire Mesh, #4 & #5 rebar
Insulation: 2” Dow Styrofoam (Close Celled)
Wall thickness: 8” (2” concrete, 2” insulation, 4” concrete)
Connection Options: Welded, Bolted, or “Pin” (recessed so hidden)
Joint Preparation: Backer Rod w/ Caulk & Grout, or Vinyl Patch
Electrical Wiring: Rigid Conduit & Boxes can be cast into panels
Erection SF per Day: 2,500 SF per Day (depending on design)
NOTE: This information is for general reference only and is subject to change with every design.